- Circuit Breakers[58]
- Contactors[10]
- Electrical Contacts and Contact Materials[1]
- Starters[6]
- Relays[10]
- Voltage Regulators/Stabilizers[10]
- Gasoline Generators[4]
- Generator Parts & Accessories[4]
- Diesel Generators[13]
- Current Meters[5]
- Other Machinery[1]
- Frequency Meters[3]
- Other Electronic Measuring Instruments[1]
- Transformers[14]
- Alarm[8]
- Laser Equipment Parts[9]
- Other Hardware[11]
- Cast & Forged[1]
- Headlamps[3]
- CD/DVD Player Bags & Cases[1]
- LED Lamps[4]
- Emergency Lights[2]
- AC/DC Adapters[2]
- Capacitors[1]
- Inverters & Converters[10]
- Electronic & Instrument Enclosures[6]
- Other Switches[6]
- Power Meters[3]
- Energy Meters[3]
- Voltage Meters[4]
- Other Electrical Equipment[1]
- Electrical Plugs & Sockets[10]
- Terminal Blocks[2]
- Power Distribution Equipment[5]
- Limit Switches[6]
- Flow Switches[1]
- Micro Switches[1]
- Fuses[2]
- Fuse Components[2]
- LED Headlamps[1]
- Chargers[2]
- Other Lights & Lighting Products[8]
- Energy Saving & Fluorescent[1]
- Motorcycle Helmets[1]
- Temperature Instruments[1]
- Other Police & Military Supplies[1]
- Contact Person : Ms. Chen Scarlett
- Company Name : Wenzhou Fullwill Electric Co., Ltd.
- Tel : 86-577-61728833
- Fax : 86-577-61728822
- Address : Zhejiang,Wenzhou,Tengfei Road 8-1#, Dongfeng Industrial Zone, Liushi Town
- Country/Region : China
- Zip : 325604
DPX series molded case circuit breaker(circuit breaker,mccb)
Detailed Product Description
DPX series molded case circuit breaker(circuit breaker,mccb)
1.Application
DPX series mouled case circuit breaker applies to the circuit with AC50/60Hz,rated insulation voltage 690V or below,and rated current of 250A.
It alao can be used as unfrequent conversion of line and unfrequency,overload protection,short circuit protection and over-voltage protection device.
2.Specification
Type | DPX-125 | DPX-250 | |||||
DPX-E | DPX | DPX | DPX | DPX-E | DPX | ||
Pole number | 3-4 | 3-4 | |||||
Rated current Im(A) | 16~125 | 25~250 | |||||
The electrical characteristic satisfies EN60947-2 | |||||||
Rated working voltage Ue 50/60Hz | 500 | 690 | |||||
Rated working voltage Ue(V) | 250 | 250 | |||||
Rated insulation voltage Ui(V) | 500 | 690 | |||||
Rated impulse voltage Uimp(KV) | 6 | 8 | |||||
Usage group | A | A | |||||
Moulded case switch type | E | H | L | ||||
Limited breaking capacity(kA) | 230/240V | 22 | 35 | 50 | 60 | 100 | 170 |
400/415V | 16 | 25 | 36 | 36 | 70 | 100 | |
400V | 10 | 18 | 20 | 30 | 60 | 70 | |
480/500V | 8 | 12 | 14 | 25 | 40 | 40 | |
600V | 20 | 25 | 25 | ||||
690V | 16 | 20 | 20 | ||||
250V | 16 | 25 | 30 | 36 | 40 | 40 | |
Used breaking capacity Icos(Icu) | 100 | 50 | 50 | 100 | 75 | 50 | |
Short-circuit closed capacity(400V) | 32 | 52.5 | 75.6 | 75.6 | 154 | 220 | |
Short-time withstand current Icw(Ka) | |||||||
Life(open,close for time) | mechanical | 7000 | 7000 | ||||
Electrical | 1000 | 1000 |